anand eurovac on trolley suction unit (high vacuum on trolley suction unit for easy accessibility)
- Bacterial Filter
- Autoclavable / Reusable
- ABS Plastic molded Housing: On four castors with Foot Switch.
- Electronic Sensor: Sensor to prevent splash droplets to enter the pump. The motor will stop and a beep will indicate this.
- Oil-free Diaphragm Pump: No-oil maintenance-free diaphragm pump.
Our most popular Eurovac is also available on a sturdy wheeled trolley for easy accessibility with or without an (on/off) foot switch.
MAIN APPLICATIONS
Intensive Care Unit
Room / Ward
Dental Practice
Home Care
Eye / ENT
TECHNICAL SPECIFICATION:
Housing | ABS Plastic Moulded on four castors |
Max. Vacuum / LPM | -575 mm Hg, 45 Ltrs / min |
Pump Type | Diaphragm pump |
Jars | 2 x 2 Ltr. PC Jar |
Filter | Bacterial Filter Autoclavable / Reusable |
Tubing | 8 mm ID x 2 mtr. (Silicon) |
Vacuum Gauge | 6.25 cm dia 0-760 mm Hg |
Power Supply | 220 V AC, 50 / 60 Hz, 90 Watt |
Noise Level | 55 dB A ± 3 |
Dimensions | 48 x 48 x 114 cms |
Net Weight | 8 Kg + 9 Kg Trolley |
Overflow Safety | Mechanical / Electronic Acoustic Alarm |
Cleaning and Disinfecting:
After each use, jars, lids, overflow cut off valve, catheters, etc.
should be cleaned thoroughly. When cleaning is necessary after infective fluid has been evacuated, the jars, lids, cut off valve and tubing can be sterilized by autoclaving upto 120°C for 20 minutes. Alkaline cleaning agents and disinfectants based on phenyel may not be used. Adherence to hospital directives on hygiene is of prime importance. The instructions provided by the suppliers of cleaning agents as well as by the manufacturers of sterilization
and/or disinfection units must also be followed, where application, temperature, process duration and airing, etc. are concerned.
Direction to use
Cleaning and Disinfecting:
- After each use, jars, lids, overflow cut off valve, catheters, etc.
should be cleaned thoroughly. When cleaning is necessary after infective fluid has been evacuated, the jars, lids, cut off valve and tubing can be sterilized by
autoclaving upto 120°C for 20 minutes. Alkaline cleaning agents and disinfectants based on phenyel may not be used. Adherence to hospital directives on hygiene is of prime importance.
The instructions provided by the suppliers of cleaning agents as well as by the manufacturers of sterilization
and/or disinfection units must also be followed, where application, temperature, process duration and airing, etc. are concerned. - Keep the Eurovac On Trolley suction unit on the trolley and fix the nuts from the bottom of the TOP panel base as shown in the picture.
Hang the 2 jars on the bottle hanger as shown.
Warranty
- Manufacturer/Importer warranty of 1 Year against manufacturing defect
- Service and Warranty are handled by the manufacturer/importer directly for this product
- DENTAL EXPRESS will not be liable to replace the Products and the liability to replace any such Product is that of the Manufacturer/Importer
- DENTAL EXPRESS and the Buyer acknowledge that the Products purchased/usedare a subject matter of original Manufacturer/Importer’s warranties only
PACKAGING
- 1 x Suction Unit
- 1 x 2 Ltr Jar