anand eurovac on trolley suction unit (high vacuum on trolley suction unit for easy accessibility)

Rs. 27,795.00
  • Bacterial Filter
  • Autoclavable / Reusable
  • ABS Plastic molded Housing: On four castors with Foot Switch.
  • Electronic Sensor: Sensor to prevent splash droplets to enter the pump. The motor will stop and a beep will indicate this.
  • Oil-free Diaphragm Pump: No-oil maintenance-free diaphragm pump.

    Our most popular Eurovac is also available on a sturdy wheeled trolley for easy               accessibility with or without an (on/off) foot switch.

 MAIN APPLICATIONS
 Intensive Care Unit
 Room / Ward
 Dental Practice
 Home Care
 Eye / ENT

TECHNICAL SPECIFICATION:

Housing ABS Plastic Moulded on four castors
Max. Vacuum / LPM -575 mm Hg, 45 Ltrs / min
Pump Type Diaphragm pump
Jars 2 x 2 Ltr. PC Jar
Filter Bacterial Filter Autoclavable / Reusable
Tubing 8 mm ID x 2 mtr. (Silicon)
Vacuum Gauge 6.25 cm dia 0-760 mm Hg
Power Supply 220 V AC, 50 / 60 Hz, 90 Watt
Noise Level 55 dB A ± 3
Dimensions 48 x 48 x 114 cms
Net Weight 8 Kg + 9 Kg Trolley
Overflow Safety Mechanical / Electronic Acoustic Alarm

Cleaning and Disinfecting:

After each use, jars, lids, overflow cut off valve, catheters, etc.
should be cleaned thoroughly. When cleaning is necessary after infective fluid has been evacuated, the jars, lids, cut off valve and tubing can be sterilized by autoclaving upto 120°C for 20 minutes. Alkaline cleaning agents and disinfectants based on phenyel may not be used. Adherence to hospital directives on hygiene is of prime importance. The instructions provided by the suppliers of cleaning agents as well as by the manufacturers of sterilization
and/or disinfection units must also be followed, where application, temperature, process duration and airing, etc. are concerned.

Direction to use

Cleaning and Disinfecting:

  • After each use, jars, lids, overflow cut off valve, catheters, etc.
    should be cleaned thoroughly. When cleaning is necessary after infective fluid has been evacuated, the jars, lids, cut off valve and tubing can be sterilized by
    autoclaving upto 120°C for 20 minutes. Alkaline cleaning agents and disinfectants based on phenyel may not be used. Adherence to hospital directives on hygiene is of prime importance.
    The instructions provided by the suppliers of cleaning agents as well as by the manufacturers of sterilization
    and/or disinfection units must also be followed, where application, temperature, process duration and airing, etc. are concerned.


  • Keep the Eurovac On Trolley suction unit on the trolley and fix the nuts from the bottom of the TOP panel base as shown in the picture.
    Hang the 2 jars on the bottle hanger as shown.

 

     Warranty

  • Manufacturer/Importer warranty of 1 Year against manufacturing defect
  • Service and Warranty are handled by the manufacturer/importer directly for this product
  • DENTAL EXPRESS will not be liable to replace the Products and the liability to replace any such Product is that of the Manufacturer/Importer
  • DENTAL EXPRESS and the Buyer acknowledge that the Products purchased/usedare a subject matter of original Manufacturer/Importer’s warranties only

   PACKAGING

  • 1 x Suction Unit
  • 1 x 2 Ltr Jar

 