anand eurovac ac-dc suction unit

Original price Rs. 22,850.00 - Original price Rs. 22,850.00
Original price
Rs. 22,850.00
Rs. 22,850.00 - Rs. 22,850.00
Current price Rs. 22,850.00
  • Housing: ABS Plastic molded Housing
  • Electronic Sensor: To prevent splash droplets to enter the pump. The motor will stop and a beep will indicate this.
  • Vacuum Gauge: 2.5 inches round vacuum gauge.
  • Oil-free Diaphragm Pump: No-oil maintenance-free diaphragm pump.

 Battery operated Suction Unit designed for use in Ambulances and Hospital Carts.

INDICATIONS:

Hospital Crash Carts
Patient Transfer
EMS / Ambulance
Long Term Home Care
Tracheostomy
Bed Side

GUIDELINES FOR USE:

Safety Jar: Safety jar with electronic overflow monitoring sensor and bacterial filter is at the back

Negative Pressure: Before the unit is put to use, required vacuum must be set by occluding the
safety jar nozzle and controlling the release valve. Fully tightened (clockwise) vacuum control
knob means full vacuum.


As the flow rate is high 3/4th filling of the jar is recommended. The lid has a built-in
antifrothing device. The jar is easier to clean if a little water or disinfectant is put into it prior
to suction operation. The safety jar must, however, remain dry. Tubing after use can be
brittle and must be changed.

 

TECHNICAL SPECIFICATION:

Housing ABS Plastic Moulded
Max. Vacuum / LPM -600 mm Hg, 55 Ltrs / min
Pump Type Diaphragm pump
Jars 1 x 2 Ltr. PC Jar
Filter Bacterial Filter Autoclavable / Reusable
Tubing 8 mm ID x 2 mtr. (Silicon)
Vacuum Gauge 6.25 cm dia 0-760 mm Hg
Power Supply 220 V AC, 50 / 60 Hz, 70 Watt
Noise Level 55 dB A ± 3
Dimensions 43 x 22 x 37 cms
Net Weight 11 Kg
Overflow Safety Mechanical / Electronic Acoustic Alarm

.VACUUM AT ALTITUDES:

The specified maximum vacuum refers to sea level. According to local conditions and barometric pressure,
slight deviations in vacuum reading may be noted. The table below shows several factors, by which the
indicated maximum vacuum value must be multiplied, according to the altitude of location where the
measurement is carried out.
Location/Maximum Vacuum
Location Sea level 1000m 2000m 4000m
Factor 1 0.88 0.78 0.6

 

Direction to use

GUIDELINES FOR USE:
Safety Jar: Safety jar with electronic overflow monitoring sensor and bacterial filter is at the back
Negative Pressure: Before the unit is put to use, required vacuum must be set by occluding the
safety jar nozzle and controlling the release valve. Fully tightened (clockwise) vacuum control
knob means full vacuum.
As the flow rate is high 3/4th filling of the jar is recommended. The lid has a built-in
antifrothing device. The jar is easier to clean if a little water or disinfectant is put into it prior
to suction operation. The safety jar must, however, remain dry. Tubing after use can be
brittle and must be changed.

Cleaning and Disinfecting:

After each use, jars, lids, overflow cut off valve, catheters, etc.
should be cleaned thoroughly. When cleaning is necessary after infective fluid has been evacuated, the jars, lids, cut off valve and tubing can be sterilized by autoclaving upto 120°C for 20 minutes. Alkaline cleaning agents and disinfectants based on phenyel may not be used. Adherence to hospital directives on hygiene is of prime importance. The instructions provided by the suppliers of cleaning agents as well as by the manufacturers of sterilization
and/or disinfection units must also be followed, where application, temperature, process duration and airing, etc. are concerned.

STEP 1:
Connect the short silicone tube, marked as (A) to the two litre plastic jar lid marked as (B) in the figure above.
STEP 2:
Safety jar with filter on the top are fitted at the back. Connect the other end of the tube A to the filter at the back of the unit.
STEP 3:
Connect the long silicone tube to the nozzle marked Patient on the two litre plastic jar lid.
STEP 4:
Attach the power cord to the socket on the side and connect the plug to the electrical mains supply.
STEP 5:
Switch the unit on and it is ready for use.

Warranty

  • Manufacturer/Importer warranty of 1 Year against manufacturing defect
  • Service and Warranty are handled by the manufacturer/importer directly for this product
  • DENTAL EXPRESS will not be liable to replace the Products and the liability to replace any such Product is that of the Manufacturer/Importer
  • DENTAL EXPRESS and the Buyer acknowledge that the Products purchased/usedare a subject matter of original Manufacturer/Importer’s warranties only