anand flovac-50 suction unit -60ltr
Oil-free Diaphragm Pump: No-oil maintenance free diaphragm pump.
-
Benefits:
- Non corrosive and shockproof Suction Unit has piston pumps on 220 – 230 V Motors (180 watts). No lubrication
is required and it is not for continuous drainage of body cavities. - The panel has a vacuum gauge with release valve,2 safety jars, & an on/off rocker switch a 2-way changeover lever for collection in one jar at a time.
- Additional 2 volt footswitch enables the user to activate and deactivate the pump from a distance. The main
switch on the panel must be on the ‘On’ position. - Before each use, the required vacuum can be obtained by occluding the patient tube.
A Sturdy Suction unit for major Surgical procedures where the blood loss is more than usual. 2 (PSU) Jars of 4 Ltrs. are mounted which are autoclavable.
- MAIN APPLICATIONS
- Emergency Department
- Intensive Care Unit
- OT / Surgery
- Obstetrics
- Gastroenterology
TECHNICAL SPECIFICATIONS:
Housing | Plastic Moulded on two wheels |
Max. Vacuum / LPM | - 700 mm Hg, 60 Ltrs / min |
Pump Type | Diaphragm pump |
Jars | 2 x 4 Ltrs. Polysulfone (PSU) Jars |
Filter | Bacterial Filter Autoclavable / Reusable |
Tubing | 10 mm ID x 2 mtr. (PVC) |
Vacuum Gauge | 6.25 cm dia 0-760 mm Hg |
Power Supply | 220 V AC, 50 / 60 Hz, 180 Watt |
Noise Level | 55 dB A ± 3 |
Dimensions | 46 x 34 x 86 cms |
Net Weight | 22 Kg |
Overflow Safety | Mechanical & Electronic Sensor |
CLEANING AND DISINFECTING: After each use, jars, lids, overflow cut off valve, catheters, etc. should be
cleaned thoroughly. When cleaning is necessary after infective fluid has been evacuated, the jars, lids and cut
off valve can be sterilized by autoclaving upto 120° C for 20 minutes. Alkaline cleaning agents and disinfectants
based on phenyel may not be used.
Adherence to hospital directives on hygiene is of prime importance. The instructions provided by the suppliers
of cleaning agents as well as by the manufacturers of sterilization and/or disinfection units must also be
followed, where application, temperature, process duration and airing, etc. are concerned.
Direction to Use
CLEANING AND DISINFECTING: After each use, jars, lids, overflow cut off valve, catheters, etc. should be
cleaned thoroughly. When cleaning is necessary after infective fluid has been evacuated, the jars, lids and cut
off valve can be sterilized by autoclaving upto 120° C for 20 minutes. Alkaline cleaning agents and disinfectants
based on phenyel may not be used.
Adherence to hospital directives on hygiene is of prime importance. The instructions provided by the suppliers
of cleaning agents as well as by the manufacturers of sterilization and/or disinfection units must also be
followed, where application, temperature, process duration and airing, etc. are concerned.
Before the unit is put on please see that :
‘ O’ rings on the push-in connector and safety jar legs are not worn out. Both these should be well inserted.
Jars be checked for any crack, tubing and lids be tightly placed on the jars. The angular connectors must
be inserted as far as the stop. While unplugging, twist and pull.
Adjust vacuum before use. Fully tightened clockwise knob means full vacuum.
Warranty
- Manufacturer/Importer warranty of 1 Year against manufacturing defect
- Service and Warranty are handled by the manufacturer/importer directly for this product
- DENTAL EXPRESS will not be liable to replace the Products and the liability to replace any such Product is that of the Manufacturer/Importer
- DENTAL EXPRESS and the Buyer acknowledge that the Products purchased/usedare a subject matter of original Manufacturer/Importer’s warranties only
PACKAGING
- 1 x Suction Unit
- 2 x 4Ltr Jars